-
We understand the many challenges associated with thermocouple calibration work. That is precisely why we decided to introduce the ADT875-1210 and ADT878-1210 Thermocouple Calibration Furnaces.
With an unmatched stability, uniformity and an optional on-board process calibrator, calibrating thermocouples has never been easier. With two separate units to choose from, the ADT875-1210 and ADT878-1210 furnaces include a patented multi-zone temperature control which provides a never before seen, highly stable and uniform heat source to ensure you get the best possible results from a modest investment. With metallic interchangeable inserts, users have the flexibility needed to service a wide variety of UUT’s and the durability they have come to expect from Additel. The ADT875-1210 and ADT878-1210 can be purchased with or without our on-board process calibration electronics to provide flexibility for customers who are needing the best 1200°C heat source on the market.
If thermocouple calibration and/or verification work is part of your workload, you don’t want to miss out on this opportunity to save valuable time and money with these best in class furnaces from Additel.
Temperature Control
The Additel ADT875 and ADT878 Thermocouple Calibration Furnaces have been designed with a unique and innovative way of controlling temperature and temperature gradients. We like to call it “Advanced Adaptive Control”. This exciting new design feature incorporates our patent pending wind tunnel control technology with Additel’s impressive 3-zone temperature control to provide the very best uniformity and stability possible.
Each ADT875 and ADT878 is tested and calibrated in Additel’s accredited laboratory (Brea, CA) to ensure that each unit is ready to go when the customer opens the package. The included accredited calibration certificate provides data relating to accuracy, stability and uniformity to help provide even more confidence in the testing and calibration of each and every ADT875 and ADT878 Thermocouple Calibration Furnace.
Process Electronics
Both the ADT875 and ADT878 can be ordered with Additel's Process Calibrator(PC) option. The Process Calibrator Option combines the many features foundin a thermocouple readout device and process calibrator with the ADT875 andADT878 Calibration Furnaces.This unique option includes Additel’s patented Quick-Push connectors which accommodate virtually all TC connection types. The Process option also includes the ability to measure a reference grade thermocouple and up to (4) under test channels. Channels 1 and 2 can measure mA, voltage, perform switch testing and source 24V DC. In addition to these measurement functions, the process option provides full documenting capability of creating tasks, saving"as found" and "as left" results and HART communications for simplified transmitter work. The snapshot feature allows users to capture all information displayed on the screen with a touch of the screen. This optional add-on allows for data logging of all channels using our auto step and a ramp functions. By utilizing the external reference option users can select to control to the furnace set point using an external control probe, which helps to reduce uncertainties. The external control probe feature also facilitates the handy self-calibration feature! -
• Thermocouple Calibration
• Temperature Transmitter Calibration
• Annealing / Heat Treating
• High Temperature PRT Calibration
• Industrial Temperature Sensor Verification
-
General Specifications 875-1210 878-1210[1] Temperature Range 100°C to 1210°C Display Accuracy ±1.2°C @ 100°C ±1.0°C @ 100°C ±1.2°C @ 300°C ±1.0°C @ 300°C ±1.2°C @ 600°C ±1.0°C @ 600°C ±1.6°C @ 900°C ±1.2°C @ 900°C ±2.0°C @ 1210°C ±1.5°C @ 1210°C Stability ±0.1°C Axial Uniformity (20mm zone) ±0.6°C @ 100°C ±0.4°C @ 100°C ±1.2°C @ 300°C ±0.8°C @ 300°C ±1.5°C @ 600°C ±1°C @ 600°C ±1.5°C @ 900°C ±1°C @ 900°C ±1.5°C @ 1210°C ±1°C @ 1210°C Radial Uniformity ±0.2°C @ 100°C ±0.2°C @ 100°C ±0.3°C @ 300°C ±0.3°C @ 300°C ±0.4°C @ 600°C ±0.4°C @ 600°C ±0.8°C @ 900°C ±0.6C @ 900°C ±1°C @ 1210°C ±0.8°C @ 1210°C Loading Effect ±0.5°C Environmental Conditions 8°C to 38°C guaranteed accuracy 0°C to 50°C, 0% to 90% RH non-condensing, 3000 M altitude for normal operation Storage Conditions -20°C to 60°C Immersion Depth XR style inserts = 138 mm (5.43") XS style inserts = 116 mm (4.57") (see insert ordering info for more details) Insert Size - OD 24.8 mm (0.98 inches) Heating Time 50 min: 23°C to 1210°C Cooling Time 50 mins:1210°C to 300°C 50 mins: 300°C to 50°C 55 mins:1210°C to 300°C 55 mins: 300°C to 50°C Typical Time to Stability 15 min Resolution 0.01°C Units °C, °F, and K Display 6.5 in (165 mm) color touch screen Size (H x W x D) 345 x 170 x 330 mm (13.6 x 6.7 x 13.0 in) Weight 10.6 kg (23.4 lbs) Power Requirements 115 V AC (±10%) or 230 V AC (±10%), switchable, 45-65 Hz, 580 W Mechanical Testing Vibrat ion: 2 g (10-500 Hz) , 30 min for 2 sides Impact: 4 g three times Drop test: 500 mm (19.6 in) Communication USB A, USB B, RJ45, WiFi, Bluetooth Localization English, Chinese, Japanese, Russian, German Warranty 1 year [1] 878-1210 specifications require use of an "XR" style insert. Otherwise, default to the 875-1210 specifications. Input Specifications (Process Calibrator [PC] Option) Specification 875-1210 878-1210 TC Measurement Channels Patented TC terminals: Accepting S, R, K, B, N, E, J, T, L, and U TC Measurement Accuracy Type K Ch. 1-4 (excluding sensor) ±0.182°C @ 100°C ±0.172°C @ 100°C ±0.266°C @ 300°C ±0.236°C @ 300°C ±0.310°C @ 600°C ±0.251°C @ 600°C ±0.397°C @ 900°C ±0.304°C @ 900°C ±0.517°C @1210°C ±0.382°C @ 1210°C TC Range –75 mV to 75 mV (UUT Channels 1-4) –18 mV to 18 mV (Reference Channel) TC Resolution 0.0001 mV, Input Impedance < 10Ω TC Voltage Accuracy 0.02% RD + 8μV (ch. 1-4) 0.01% RD + 8μV (ch. 1-4) 0.01% RD + 2μV (ref ch.) 0.005% RD + 2μV (Ref ch.) Internal CJC Accuracy ±0.35°C (ch. 1-4) ±0.30°C (ch. 1-4) ±0.25°C (ref ch.) ±0.20°C (ref ch.) Current Range –30 mA to 30 mA Current Accuracy ±(0.02% of rdg+ 2μA) ±(0.01% of rdg + 2μA) Current Resolution 0.0001 mA Voltage Ranges –12 V to 12 V and –30 V to 30 V Voltage Accuracy ±(0.02% of rdg+ 2mV) ±(0.01% of rdg+ 0.6mV) Voltage Resolution 0.0001 V, Input Impedance >1MΩ DC 24V Output 24 V ± 10%, MAX 60 mA Hart Communication Optional (ADT875PC and ADT878PC Models) Temperature Coefficient 0°C to 8°C and 38°C to 50°C TC Readouts: ±5 ppm/°C Current: ±5 ppm/°C Voltage: ±5 ppm/°C Switch Test Mechanical or Electrical - Channels 1 & 2 only Documentation Up to 1,000 tasks which store up to 10 results each containing as found and as left data. Snap shot feature allows for screen captures. Records auto step and ramp functions TC Measurement Specifications TC Type TEMP (°C) Error (°C)[1] 875 878 K (CH1-CH4) 100 ±0.182 ±0.172 300 ±0.266 ±0.236 600 ±0.310 ±0.251 900 ±0.397 ±0.304 1210 ±0.517 ±0.382 N (CH1- CH4) 100 ±0.273 ±0.264 300 ±0.270 ±0.243 600 ±0.309 ±0.256 900 ±0.368 ±0.285 1210 ±0.455 ±0.335 E (CH1- CH4) 100 ±0.136 ±0.126 300 ±0.153 ±0.130 600 ±0.210 ±0.154 900 ±0.291 ±0.202 1000 ±0.297 ±0.196 L (CH1- CH4) 100 ±0.223 ±0.214 300 ±0.271 ±0.241 600 ±0.308 ±0.251 900 ±0.522 ±0.448 U (CH1- CH4) 100 ±0.270 ±0.261 300 ±0.189 ±0.164 600 ±0.227 ±0.176 J (CH1- CH4) 100 ±0.186 ±0.177 300 ±0.197 ±0.168 600 ±0.256 ±0.200 900 ±0.281 ±0.197 1200 ±0.414 ±0.294 S (CH1-CH4) 100 ±1.102 ±1.094 300 ±0.924 ±0.899 600 ±0.888 ±0.837 900 ±0.868 ±0.793 1210 ±0.865 ±0.765 R (CH1- CH4) 100 ±1.080 ±1.072 300 ±0.869 ±0.844 600 ±0.804 ±0.755 900 ±0.771 ±0.699 1210 ±0.766 ±0.670 B (CH1- CH4) 250 ±3.182 ±3.170 300 ±2.645 ±2.631 600 ±1.409 ±1.379 900 ±1.049 ±1.003 1210 ±0.905 ±0.839 T (CH1- CH4) 100 ±0.194 ±0.185 300 ±0.191 ±0.166 400 ±0.217 ±0.183 S (EXT. REF) 100 ±0.277 ±0.273 300 ±0.242 ±0.229 600 ±0.249 ±0.224 900 ±0.258 ±0.220 1210 ±0.266 ±0.216 R (EXT. REF) 100 ±0.271 ±0.266 300 ±0.228 ±0.216 600 ±0.227 ±0.202 900 ±0.230 ±0.194 1210 ±0.240 ±0.192 -
Documents:
File name Upload Date Size Additel 875-1210 and 878-1210 Dry Well Calibrator Datasheet 2020.5.14 1 MB Additel 875-1210 and 878-1210 Dry Well Calibrator User Manual 2020.11.17 1.4 MB Update Packages:
File name Upload Date Size Additel 875-1210 and 878-1210 Firmware Package 2021.1.13 11.6 MB HART Temperature Library Update Package 2019.6.5 50.7 MB HART Pressure Library Update Package 2019.6.5 138.4 MB -
-
Videos:
File name ADT875-1210 and 878-1210 - Introduction