Explore the Interface

logo Additel

รุ่น 761A-BP


Description

Additel 761A-BP

Automated Pressure Calibrator
  • Automated and self-contained pressure generation and control to 1200 hPa
  • Up to 0.01%FS accuracy
  • Single pressure module
  • Control stability to 0.02 hPa
  • Portable, designed for use in the field and in the lab
  • Ability to measure two external pressure modules
  • Wi-Fi, Bluetooth, USB and Ethernet communication
  • Full HART field communicator
  • HART and profibus communication
  • Data logging and task management
  • Patented electric pump technology and improved speed


  • At Additel, innovation and continuous improvement are part of our company's culture and the products we introduce. When we set out to deliver the Additel 761A series calibrators, we knew we needed to provide breakthrough improvements and additional value to the existing line of calibrators (Additel 761 series). The ADT761A has many improvements: increased pressure range to 1,000 psi (70 bar), removable internal pressure modules, optional precision models to 0.01%FS, increased speed to pressure, ability to read two external pressure modules, touch screen display, Wi-Fi, Bluetooth, and Ethernet communications, double the original battery life, and more!

    ADT761A-BP
    The Additel 761A-BP is designed for calibration of barometer sensors. With a range of 100 to 1200 hPa and an accuracy of 0.01%FS, this unit is ideal for calibration on the bench or in the field.
  • APPLICATIONS


  • Pressure Specifications
    Specification761A-LLP761A-D761A-500761A-1K761A-APXR761A-BP
    Max Pressure Range30 inH2O (75 mbar)35 psi (2.5 bar)500 psig (35 bar.g)1,000 pisg (70 bar.g)Dependent on APXR1,200 hPasensor
    Min Pressure Range-30 inH2O (-75 mbar)-13.5 psi (-0.95 bar)-13 psi (-0.9 bar)-13 psi (-0.9 bar)Dependent on APXR100 hPasensor
    Accuracy(1)0.05%FS0.02%FS0.02%FS0.02%FS0.01%FS0.01%FS
    Stability0.005%FS or 0.05 Pa0.005%FS0.005%FS0.005%FS0.003%FS0.02 hPa
    Pressure TypeDifferential, GaugeDifferential, GaugeGauge, AbsoluteGauge, AbsoluteGauge, AbsoluteAbsolute
    Over Range Indication1.2
    Resolution6 digits
    Measurement UnitsPa, hPa, kPa, mPa, bar, mbar, psi, mmHg@0°C, cmHg@0°C, mHg@0°C, inHg@0°C, inH2O@4°C, mmH2O@4°C, cmH2O@4°C, mH2O@4°C, mmH2O@20°C, cmH2O@20°C, mH2O@20°C, inH2O@20°C, inH2O@68°F, kg/m2, mtorr, torr, lb/ft2, tsi, custom
    Barometric AccuracyN/AN/A60 Pa60 Pa60 PaN/A
    [1] One year accuracy (including 1 year stability). FS specification applies to the span of the module range.
    [2] Specification based on gauge measurement. An additional 60 pa uncertainty will need to be included when measuring in absolute mode. Applicable only for use with the ADT761A-500 and ADT761A-1K
    * Additel 761A calibrators support 160A intelligent digital pressure modules that are available for gauge, vacuum and absolute pressure from -15 psi to 60,000 psi (-1 bar to 4200 bar).For detailed specs, see the 160A pressure module data sheet.
    Electrical Specifications
    SpecificationRangeResolutionAccuracyNote
    mA MeasureAuto-ranging, ±25 or ±50 mA0.1 μA0.008%RD+0.004%FSImpedance<10Ω
    V Measure±300 mV1 μV0.008%RD+0.002%FSImpedance >1GΩ
    Auto-ranging, ±5, ±12 or ±30 V±5V:20 μV0.008%RD+0.002%FSImpedance >1MΩ
    ±12V:100 μV
    ±30V:100 μV
    Loop Power Source24 VN/A±0.24 V50 mA (Max Loading)
    mA Source0 to 2.5 mA or 2.5 to 25 mA0-2.5 mA: 0.05μA0-2.5 mA: 0.008%RD+0.1 μA20 mA @ 1KΩ
    0-25 mA:0.5μA0-25 mA: 0.008%RD+1.0 μA
    Power Source16 to 30 V1 V±0.5 V(24 V: ±0.24 V)70 mA (Max Loading)
    V Source0 to 16 V250 μV0.008%RD+0.002%FS
    Pressure SwitchMechanical Switch, Live Mechanical Switch, NPN Switch, PNP SwitchN/AN/AResponse time<10 ms. If the switch is live, voltage range will be (3-30) V
    Temperature Compensation5°C to 35°C
    Temperature CoefficientOutside of 5°C to 35°C: <±0.0005%RD+0.0001%FS/°C
    Misuse ProtectionUp to 30 V on any two sockets
    Internal Module Specification and Compatibility
    ModelinH2OmbarMediaAccuracy (%FS)(1)Burst Pressure761A-LLP761A-D761A-500761A-1K
    ADT155-20-DP025±0.25±0.62G0.2 (2)100x
    ADT155-10-DP050±0.5±1.25G0.1(3)100x
    ADT155-05-DP1±1±2.5G0.05(4)100x
    ADT155-05-DP2±2±5G0.05(4)100x
    ADT155-05-DP5±5±10G0.05(4)50x
    ADT155-05-DP10±10±25G0.05(4)20x
    ADT155-05-DP20±20±50G0.0520x
    ADT155-05-DP30±30±75G0.0520x
    ADT155-05-DP50±50±125G0.053x
    ADT155-02-DP100±100±250G0.023x
    ADT155-02-DP150±150±350G0.023x
    ADT155-02-DP300±300±700G0.023x
    ADT155-02-DP400-380 to 400-950 to 1KG0.023x
    ADT155-02-DP800-380 to 800-950 to 2KG0.023x
    ADT155-02-DP1K-380 to 1K-950 to 2.5KG0.023x
    [1] FS specification applies to the span of the module range. Accuracy includes one-year stability, except for DP025 to DP10 modules.
    [2] Accuracy is a 6 months spec, 1-year long-term drift is 0.2%FS.
    [3] Accuracy is a 6 months spec, 1-year long-term drift is 0.1%FS.
    [4] Accuracy is a 6 months spec, 1-year long-term drift is 0.05%FS.
    [5] Specification based on gauge measurement. An additional 60 pa uncertainty will need to be included when measuring in absolute mode.Applicable only for use with the ADT761A-500 and ADT761A-1K.
    General Specifications
    SpecificationDescription
    User InterfaceColor touch screen and/or keypad operation
    Four total: one electrical, high or low internal
    Channelspressure module, two external pressure modules
    Enclosure IP RatingIP31
    BatteryRechargeable Li-Ion battery, typically 16 hours of operation, recharges in less than 5 hours.
    PowerRechargeable Li-Ion battery, external power 110/220 V power adapter 27 V
    Display7” TFT touch screen 800 x 480 color
    CommunicationsUSB, LAN, Bluetooth, Wi-Fi
    Weight<17.52 lb (7.95 KG)
    Size11.77 x 7.60 x 7.56 in (299 x 193 x 192 mm)
    CertificationISO17025 accredited certificate of calibration with NIST-traceable data
    Data Storage6 GB
    Data LoggingUp to 1,000,000 readings (data and time stamped)
    HART CommunicatorRead, configure and calibrate HART devices - DD files updated periodically
    Task documentationUp to 1000 tasks can be stored with data
    Automation FunctionsSwitch test, auto step, leak test
    User Interface LocalizationEnglish, German, French, Italian, Spanish, Portuguese, Chinese, Japanese, and Russian
    Pump life>100,000 cycles
    Environmental SpecificationsOperating temperature: 32 °F to 122 °F( 0°C to 50°C)
    Compensated temperature: 32 °F to 122 °F( 0°C to 50°C)
    Storage temperature: -20°C to 60°C ( -4 °F to 120 °F)
    Humidity: <90%, non-condensing
    Vibration and ShockVibration: 4g (20 to 2,000 Hz)
    Shock: 8g, 1 meter drop test
    ComplianceCE
    Software CompatibilityACal, Additel Land and Additel Link for access via mobile application
    Warranty1 year
    Pressure Range
    TypeModelPressure RangeHigh-Range Pressure ModuleLow-Range Pressure Module
    RangeAccuracyRangeAccuracy
    Low/Differential PressureADT761A-LLP-75 to 75 mbar (-30 to 30 inH2O)DP30: -75 to 75 mbar (-30 to 30 inH2O)0.05%FSUser selectable from DP20 to DP025See Internal Module Table
    ADT761A-D-0.95 to 2.5 bar (-13.5 to 35 psi)CP35: -0.95 to 2.5 bar (-13.5 to 35 psi)0.02%FSUser selectable from DP10 to CP30See Internal Module Table
    Standard Accuracy Gauge/Absolute PressureADT761A-500-0.9 to 35 bar (-13 to 500 psi)CP500: -0.9 to 35 bar (-13 to 500 psi)0.02%FSUser selectable from CP10 to CP300See Internal Module Table
    ADT761A-1K-0.9 to 70 bar (-13 to 1000 psi)CP1K: -0.9 to 70 bar (-13 to 1000 psi)0.02%FSUser selectable from CP30 to CP600See Internal Module Table
    Precision Accuracy Gauge/Absolute PressureADT761A-30R-0.95 to 1 bar (-13.5 to 15 psi)AP30R: -0.95 to 1 bar (-13.5 to 15 psi)0.01%FSSingle sensor only
    ADT761A-50R-0.95 to 2.5 bar (-13.5 to 35 psi)AP50R: -0.95 to 2.5 bar (-13.5 to 35 psi)0.01%FSSingle sensor only
    ADT761A-100R-0.95 to 7 bar (-13.5 to 100 psi)AP100R: -0.95 to 7 bar (-13.5 to 100 psi)0.01%FSSingle sensor only
    ADT761A-300R-0.9 to 21 bar (-13 to 300 psi)AP300R: -0.9 to 21 bar (-13 to 300 psi)0.01%FSSingle sensor only
    ADT761A-500R-0.9 to 35 bar (-13 to 500 psi)AP500R: -0.9 to 35 bar (-13 to 500 psi)0.01%FSSingle sensor only
    ADT761A-1KR-0.9 to 70 bar (-13 to 1000 psi)AP1KR: -0.9 to 70 bar (-13 to 1000 psi)0.01%FSSingle sensor only

  • Documents:

    File nameUpload DateSize
    Additel 761A Automated Pressure Calibrator Datasheet 2019.8.26 0.8 MB
    ADT761A Selection Guide.pdf 2019.8.26 0.1 MB
    Additel 761A User Manual 2018.3.28 2.2 MB
    Additel 761A Battery MSDS 2020.6.11 5.2 MB
    Additel Hart Communication Manual 2020.7.28 0.4 MB

    Update Packages:

    File name Upload Date Size
    Additel 761A Firmware Package 2020.2.18 11.4 MB
    Hart Pressure Product DD Library 2020.8.20 139.4 MB




  • Selection Guide
    Models761A-LLP761A-D761A-500761A-1K761A-APXR761A-BP
    Pressure Range-75 to 75 mbar (-30 to 30 inH2O)-0.95 to 2.5 bar.g (-13.5 to 35 psig)-0.90 to 35 bar.g (-13 to 500 psig)-0.90 to 70 bar.g (-13 to 1000 psig)-0.90 to 70 bar.g (-13 to 1000 psig)100 to 1,200 hPa
    Control Stability<0.005%FS or 0.05Pa<0.005%FS<0.005%FS<0.005%FS<0.003%FS<0.02 hPa
    Number of Internal Modules222211
    Removable Internal Modules
    Differential Pressure
    Gauge Pressure
    Absolute Pressure
    Barometric Pressure
    Two External Pressure Modules
    Built-in Electric Pump
    Source/Simulate mA
    Measure mA or V
    24V Loop Power
    Pressure Switch Test
    HART/Profibus Communication
    Task Documentation
    Data Logging

  • Videos:

    File name
    Additel 761A Introduction