With advanced microprocessor technology and state-of-the-art silicon pressure sensors, the 680 series digital pressure gauges provide an accurate, reliable, and economic solution for a wide range of pressure applications. They are loaded with functionality and remarkably easy to use. To reach the best performance, every silicon pressure sensor in our gauges is specially aged, tested and screened before assembly. With data logging and wireless features, the 680W gauge can store pressure measurement data in the internal memory or display them on PC through wireless communication. The 680 series digital pressure gauges are unmatched in performance and reliability. Best of all, they are very affordable.
-
• Precision pressure measurement
• Field gauge calibration
• Pressure safety valve (PSV) testing
• Pressure regulator testing -
Gauge Pressure P/N Pressure Range Accuracy(%FS)[2] Media[3] Burst Pressure psi[1] bar V15 -15 -1 0.05 (0.1, 0.25) G,L 3× GP15 15 1 0.05 (0.1, 0.25) G,L 3× GP30 30 2 0.05 (0.1, 0.25) G,L 3× GP100 100 7 0.05 (0.1, 0.25) G,L 3× GP150 150 10 0.05 (0.1, 0.25) G,L 3× GP300 300 20 0.05 (0.1, 0.25) G,L 3× GP500 500 35 0.05 (0.1, 0.25) G,L 3× GP1K 1000 70 0.05 (0.1, 0.25) G,L 3× GP3K 3000 200 0.05 (0.1, 0.25) G,L 3× GP5K 5000 350 0.05 (0.1, 0.25) G,L 3× GP10K 10000 700 0.05 (0.1, 0.25) G,L 3× GP15K 15000 1000 0.05 (0.1, 0.25) G,L 2× GP20K 20000 1400 0.05 (0.1, 0.25) G,L 1.5× GP25K 25000 1600 0.1 (0.25) G,L 1.5× GP30K 30000 2000 0.1 (0.25) G,L 1.5× GP36K 36000 2500 0.1 (0.25) G,L 1.5× GP40K 40000 2800 0.1 (0.25) G,L 1.35× GP50K 50000 3500 0.1 (0.25) G,L 1.2× GP60K 60000 4200 0.1 (0.25) G,L 1.1× [1] Sealed gauge pressure for above 1,000 psi. [2] FS specification applies to the span of the range. [3] G=Gas, L=Liquid Compund Pressure P/N Pressure Range Accuracy(%FS)[2] Media[3] Burst Pressure psi[1] bar CP15 ±15 ±1 0.05(0.1, 0.25) G,L 3× CP30 -15 to 30 -1 to 2 0.05(0.1, 0.25) G,L 3× [1] Sealed gauge pressure for above 1,000 psi. [2] FS specification applies to the span of the range. [3] G=Gas, L=Liquid Model ADT680 ADT680W Description Digital Pressure Gauge Wireless Digital Pressure Gauge with Data Logging Wireless Communication (ADT680W only) N/A Wireless Frequency: 2.4G ISM Bands, 20 meter range Number of wireless Channels: Chanel 1-15 Software: Wireless network demo software included read upto 20 gauges. Data Logging (ADT680W only) N/A Storage Capacity: 140,000 readings (time, pressure, and temperature) Storage Interval: Adjustable from 1-9999 Sec Single-button-press data logging enabled Key Lockout: When the gauge is in auto-storing mode, the front panel buttons will be automatically locked. Pressure Type Gauge Pressure, compound Pressure Accuracy 0.05%, 0.1% or 0.25%FS Update Rate 10 times/Sec ,3 times /Sec (default), 1 time /Sec ,1 time/15 Sec Operating Temperature 14°F to 122°F (-10°C to 50°C) Compensated Temperature 14°F to 122°F (-10°C to 50°C), accuracy guaranteed Storage Temperature -4°F to 158°F (-20°C to 70°C) Overload Pressure 1.2X Dimensions 100mm x 40mm, total height:157mm Weight 500g Filtering Averaging (3 to 10 samples) or low-pass first-order filter. Max/Min data capture Saves Max and Min data during pressure measurement. Engineering units Pa, kPa, MPa, bar, mba, psi, kgf/cm2, mmH2O, mmHg, inH2O, inHg, ozf/in, %, °C, °F extend units: inH2O(20°C), inH2O(60°F), mmH2O(20°C), mmH2O(15°C), ftH2O(60°F), or ftH2O(4°C) Display LCD Specification: FSTN-LCD,Visual scope 36x61mm Full 5 digits,15.2mm High 7 segment analog bar graph scaled from 0-100% of FS Backlight: White Backlight Duration: Not auto off,15,30,45,60 seconds optional Auto off Disabled,15, 30, 45, 60, 90, or 120 Minutes Compliance Certificates:CE R&TTE, FCC ID, IC ID Protection Level: IP67 Vibration: 5g(20-2000Hz) Shock resistance: 100g/11ms Pressure Port ≤15,000 PSI: 1/4NPT male, 1/2NPT male, 1/4BSP male, 1/2BSP male, M20×1.5 male >15,000 PSI: 1/4HP female or 1/4HP male *1/4HP female: Autoclave F-250-C, 9/16" - 18 UNF-2B *1/4HP male: Autoclave M-250-C, 9/16" - 18 UNF-2A Other connections available per request. Overpressure Alarm Display will flash over 120%FS Battery voltage Indicator Displays the battery life remaining. When the battery voltage is too low, the gauge will power-off automatically. Overpressure Record Gauge will record max pressure data when the gauge is over pressured by 120% of FS. Leakage test In leak test mode, the gauge will record beginning pressure, ending pressure, and show the difference ΔP. Factory Reset Resets all settings back to factory default, except the calibration parameters. Warranty 1 year -
Documents:
File name Upload Date Size Additel 680 Digital Pressure Gauges Datasheet 2018.3.27 0.2 MB Additel 680 Digital Pressure Gauges User Manual 2018.3.27 17 MB Additel Pressure Gauge Selection Guide 2019.5.21 0.3 MB Additel Gauge Resolution Datasheet 2020.3.11 0.2 MB Update Packages:
File name Upload Date Size 0 MB -
-
Videos:
File name Additel 680W Wireless and Data Logging Setup Additel 680 Video Demo