A highly integrated multifunction calibrator featuring several patented technologies, the 223A is an ultra-compact, rugged, and easy to use hand-held device for sourcing, simulating and measuring pressure, temperature, and electrical signals. Its smartphone-like menu and interface make the operation simpler and easier. With HART communication capability, the 223A is ideal for calibrating, maintaining, and troubleshooting HART instrumentations. Automation and documentation capabilities make the 223A a turnkey solution.
-
The 223A multifunction calibrator is a process tool for measuring, sourcing and simulating mA, mV, V, RTDs, thermocouples, ohms, frequency, pulses and pressure, captures switch values and provides 24 V loop power.
• Electrical
Resistance measurement / simulation
Voltage measurement / generation
Current measurement /generation
Frequency measurement / generation
Pulse counting/generation
24 VDC loop supply
Switch sensing
• Temperature
RTD measurement /simulation
TC measurement /simulation
• Accredited Calibration with data
• Warranty:
3 years -
Measurement Accuracy Range Resolution Accuracy Voltage DC ±75.0000 mV 0.1μV 0.01%RD + 3.75 μV ±30.0000 V 0.1 mV 0.01%RD + 1.5 mV Current DC ± 30.0000 mA 0.1μA 0.01%RD + 1.5 μA Resistance Two-wire 0 to 400.000 Ω 1mΩ 0.02%RD + 0.02 Ω Three-wire 0 to 400.000 Ω 1mΩ 0.02%RD + 0.02 Ω Four-wire 0 to 400.000 Ω 1mΩ 0.01%RD + 0.02 Ω Two-wire 0 to 4000.00 Ω 10mΩ 0.02%RD + 0.2 Ω Three-wire 0 to 4000.00 Ω 10mΩ 0.02%RD + 0.2 Ω Four-wire 0 to 4000.00 Ω 10mΩ 0.01%RD + 0.2 Ω Frequency 1 to 50000.0 Hz 0.1Hz 0.005%RD + 1 Hz Pulse 0 to 999999 1 N/A Limit Switch For the contact with potential, the voltage within the range 3V to 24V. Source Accuracy Voltage DC -10.000 to 75.000mV 1μV 0.02%RD + 4.25 μV 0 to 12.0000 V 0.1mV 0.02%RD + 0.6 mV Current DC 0 to 22.000 mA 1μA 0.02%RD + 1.1 μA Resistance 1 to 400.00 Ω 10mΩ 0.02%RD + 0.02 Ω 1 to 4000.0 Ω 100mΩ 0.03%RD + 0.4 Ω Frequency 0 to 50000.0 Hz 0.1Hz 0.005%RD + 1 Hz Pulse 0 to 999999 1 N/A DC24V N/A N/A 0.5V Thermocouple Measurement and Source Accuracy Measure and Simulate Standard Temperature Range (oC) Accuracy (oC) Measure Source S IEC 584 -50 to 1768 -50 to400 1 1.1 400 to 1000 0.6 0.6 1000 to1768 0.7 0.8 R IEC 584 -50 to 1768 -50 to 200 1.4 1.4 200 to 500 0.6 0.6 500 to 1768 0.6 0.7 B IEC 584 0 to 1820 50 to 450 3.8 3.8 450 to 800 0.9 0.9 800 to 1820 0.6 0.7 K IEC 584 -270 to 1372 -250 to -200 1 1.1 -200 to -100 0.4 0.5 -100 to 600 0.3 0.3 600 to 1372 0.4 0.5 N IEC 584 -270 to 1300 -250 to -200 1.5 1.6 -200 to -100 0.5 0.6 -100 to 1300 0.4 0.5 E IEC 584 -270 to 1000 -250 to -200 0.6 0.7 -200 to -100 0.3 0.3 -100 to 0 0.2 0.2 0 to 700 0.2 0.3 700 to 1000 0.2 0.4 J IEC 584 -270 to 1200 -210 to -100 0.3 0.3 -100 to 1200 0.3 0.4 T IEC 584 -270 to 400 -250 to -200 0.8 0.9 -200 to 0 0.4 0.4 0 to 400 0.2 0.2 C ASTM E988 0 to 2315 0 to 1000 0.5 0.5 1000 to 1800 0.7 0.9 1800 to 2315 1 1.4 D ASTM E988 0 to 2320 0 to 100 0.5 0.5 100 to 1100 0.4 0.5 1100 to 2000 0.6 0.9 2000 to 2320 0.9 1.3 G ASTM E1751 0 to 2315 0 to 200 2.4 2.4 200 to 400 0.5 0.5 400 to 1400 0.4 0.5 1400 to 2315 0.7 1 L DIN43710 -200 to 900 -200 to -100 0.2 0.3 -100 to 400 0.2 0.2 400 to 900 0.2 0.3 U DIN43710 -200 to 600 -200 to 0 0.4 0.4 0 to 600 0.2 0.3 *Accuracy with external cold junction; for internal cold junction add 0.1°C (k=2) Measurement Accuracy Measure and Simulate Standard Temperature Range (°C) Accuracy (°C) Measure (2W/3W) Measure (4W) Source Pt10(385) IEC 751 -200 to 850 -100 to 200 0.65 0.6 0.65 200 to 600 0.82 0.72 0.82 600 to 850 0.96 0.82 0.96 Pt100(385) IEC 751 -200 to 850 -100 to 200 0.15 0.1 0.15 200 to 600 0.26 0.16 0.26 600 to 850 0.34 0.2 0.34 Pt100(3916) JIS 1604 -200 to 850 -100 to 200 0.15 0.1 0.15 200 to 600 0.26 0.16 0.26 600 to 850 0.33 0.2 0.33 Pt100(3926) Minco Application Aid #18 -200 to 850 -100 to 200 0.15 0.1 0.15 200 to 600 0.26 0.16 0.26 600 to 850 0.33 0.2 0.33 Pt500(385) IEC 751 -200 to 850 -100 to 200 0.2 0.16 0.36 200 to 600 0.32 0.22 0.54 600 to 850 0.4 0.27 0.67 Pt1000(385) IEC 751 -200 to 850 -100 to 200 0.1 0.05 0.25 200 to 600 0.2 0.1 0.42 600 to 850 0.27 0.14 0.54 Cu10(427) Minco Application Aid #18 -100 to 260 -100 to 260 0.61 0.56 0.61 Cu50(428) GOST 6651-94 -50 to 150 -50 to 150 0.17 0.13 0.17 Cu100(428) GOST 6651-94 -50 to 150 -50 to 150 0.12 0.09 0.12 Ni120(672) Edison curve #7 -100 to 260 -100 to 260 0.07 0.05 0.07 Ni100(618) DIN 43760 -100 to 260 -100 to 260 0.08 0.06 0.08 General Specifications Operating Temperature -10°C to 50°C Storage Temperature -20°C to 60°C Humidity <90%, non-condensing European Compliance CE Mark Protection Level IP30 Display 3.5 inch TFT color screen Electrical Connection Ø4mm sockets and flat mini-jack thermocouple socket RS232 Interface Standard RS232-DB9 socket Size 3.9" x 7.6" x 2.0" (100mm x 192mm x 52mm) Weight 1.6 lb (0.7 kg) Power Supply Polymer Li-ion rechargeable battery,or 10V DC adaptor Battery Rechargeable Li-ion battery (included) Battery Life 15 hours uninterrupted use Battery life will be reduced when 24V is applied Battery Charge 110V/220V external power adapter (included) Pressure Specifications (222A & 223A) The 160A series Intelligent Digital Pressure Modules are available for gauge, vacuum and absolute pressure from -15 psi to 10,000 psi (-1 bar to 700 bar). Accuracy from 0.02% FS includes operation over 14°F to 122°F (-10°C to 50°C), one year stability and calibration uncertainty. For detail specification refer to pressure modules datasheet. -
Documents:
File name Upload Date Size Additel 223A Documenting Process Calibrator User Manual 2019.3.11 19 MB Additel Multifunction Process Calibrator Datasheet 2018.3.28 0.1 MB Additel Multifunction Process Calibrator Selection Guide 2019.5.21 0.2 MB Update Packages:
File name Upload Date Size Additel 223A Firmware Update Package 3.5 MB -